  1. GE SECURITY ALARM PANEL MANUAL
  2. GE SECURITY ALARM PANEL CODE
  3. GE SECURITY ALARM PANEL SERIES

The regular user codes are just used to arm and disarm the system.

GE SECURITY ALARM PANEL CODE

The installer code is generally only used to make the system altering changes such as changing timer lengths or adding/editing/deleting sensors. There 11 total user codes, 9 of which are suitable for day to day use on the alarm system: the installer code, master code, duress code, and 8 standard user codes. User CodesĪnother aspect of the Simon XT and Simon XTi-5 that is exactly the same is the number of user codes. They have numerous options for nearly any sensor type that you might want. The Simon XT and Simon XTi-5 are compatible with all of Interlogix wireless sensors. But that does not include anything like glass break detectors, temperature sensors, flood/leak detectors, et cetera. For instance a home with 20 windows, 5 doors, 5 motion detectors, and 10 smoke detectors would completely max out the Simon alarm system. But if you have a large home with a lot of openings on the ground floor or a large commercial site, 40 zones can be eaten up in no time. 40 zones is plenty for almost any residential application and can be enough for small commercial installations. So if you used 2 hardwired zones you would have 38 zones left that can be used for wireless sensors. But those do count towards that maximum of 40 total zones. And, as mentioned previously, the alarm panels have up to 2 inputs available for hardwired zones. Zonesīoth alarm systems have a maximum capacity of 40 zones. Everything else will be contained within the main control and communicate to other alarm components wirelessly. And if you are planning on using a telephone landline for communications, that would need to be wired as well. There are numerous other situations that the output can be used for. For instance, you can connect a relay with a power supply and hardwired siren to have a more powerful sounder than the one that is built into the panel. And one of those zones can actually be used as an output. However, the both Simon panels are capable of utilizing up to 2 hardwired zones. For the most part, this is the only wiring needed for your Simon alarm system. The first exception is the wire from the plug in power transformer to the Simon panel, of course. The Simon XT and Simon XTi-5 are both fully wireless alarm systems (with small exceptions). However, the two systems still manage to differentiate themselves by having very different user interfaces which we will focus on after looking at the similarities.

ge security alarm panel

In fact, as we will talk about, when you look at the behind the scenes features or foundation of the alarm system they are nearly identical. In many ways the Simon XT and Simon XTi-5 very similar systems. Currently, we carry 2 Simon models: Simon XT and Simon XTi-5. To us, this really speaks to how good the Simon really is. Through it all, the Simon security system has survived and seen many new models.

ge security alarm panel

GE SECURITY ALARM PANEL SERIES

Since then, there have been a series of company buyouts and mergers: from Sentrol to GE Security to UTC to Interlogix. The original Simon was created by a company called ITI. The Simon line of alarm systems originated about 2 decades ago in the late 1990’s.

  • Total Connect 2.0 Package Monitoring Add-Ons.
  • Central Station Alarm Monitoring Services.
  • The power light will flash if the system has a low battery condition.
  • Note that the power light is on if the primary power is on.
  • GE SECURITY ALARM PANEL MANUAL

    (Instructions in the manual at the bottom of this page)

  • If Zone 8 lights up - Loss of System Time - This light illuminates when there has been a loss of power and your system clock needs to be reset.
  • If Zone 7 lights up - Failure Communicate - This light illuminates when there is a failure to communicate between your system and central station.
  • The zone light(s) illuminated corresponds to the system fault(s) below: 6 - Telephone line cut/line trouble (The service light will remain on until the telephone trouble clears and a user code is entered.) 7 - Auxillary Comm Device Fail - Radio backup has failed.
  • If Zone 6 lights up - Telephone Fault - Press the key.
  • The alarm memory feature will flash zone/s that created alarms and will light steady the zone/s that were bypassed during the last alarm.
  • To trouble shoot: Press *2 on the keypad.
  • Why is my keypad beeping periodically and/or service light on?